PicoScope 6000 — The Highest Performance USB Scopes

Highest Performance USB Oscilloscopes

The fastest sampling, highest bandwidth and deepest memory of any USB oscilloscope on the market today.
  • 4 channels.
  • 500 MHz bandwidth.
  • 5 GS/s real–time sampling.
  • 2 GS memory!
  • Arbitrary waveform generator.
  • Serial decoding.
  • Mask limit testing.
  • USB 3.0 interface.

Description

Over two decades of oscilloscope design experience has resulted in the PicoScope 6000 Series — the ultimate in USB oscilloscope design.

High bandwidth,high sampling rate

With 250 MHz to 500 MHz analog bandwidths complemented by a real-time sampling rate of 5 GS/s, the PicoScope 6000 Series scopes can display single-shot pulses with 200 ps time resolution. Equivalent time sampling (ETS) mode boosts the maximum sampling rate to 50 GS/s, giving an even finer timing resolution of 20 ps for repetitive signals.

Huge buffer memory

The PicoScope 6000 Series gives you the deepest buffer memory available as standard on any oscilloscope at any price. The SuperSpeed USB 3.0 interface and hardware acceleration ensures that the display is smooth and responsive even with long captures. Other oscilloscopes have high maximum sampling rates, but without deep memory they cannot sustain these rates on long timebases. The 2-gigasample buffer on the PicoScope 6404D can hold two 200 ms captures at the maximum sampling rate of 5GS/s. To help manage all this data, PicoScope can zoom up to 100 million times using a choice of two zoom methods. There are zoom buttons as well as an overview window that lets you zoom and reposition the display by simply dragging with the mouse
Huge buffer memory

Store up to 10,000 waveforms in the buffer

Store up to 10,000 waveforms in the buffer

Ever spotted a glitch on a waveform, but by the time you’ve stopped the scope it has gone? With PicoScope you no longer need to worry about missing glitches or other transient events.

With PicoScope you can divide the buffer memory into as many as 10,000 individually triggered segments.  If you manage to completely fill the waveform buffer PicoScope will use the first in, first out principle to ensure that the buffer always contains the latest waveforms.

Use the visual buffer navigator to scan through the segments, or use the mask limit tools to scan through, highlighting any that fail.

Arbitrary waveform and function generator

Arbitrary waveform and function generator

Every model includes a built-in DC to 20 MHz function generator with sine, square, triangle and DC waveforms. D models add a built-in 12-bit, 200 MS/s arbitrary waveform generator with a 64,000 sample buffer memory. You can import arbitrary waveforms from data files, oscilloscope waveforms or create and modify them using the built-in graphical AWG editor.

 

Features

Over two decades of PC–based design experience and listening to your needs and desires has resulted in the PicoScope 6000 Series — the ultimate in USB oscilloscope design.

Analog and digital low-pass filtering

Analog and digital low-pass filtering

Each input channel has its own digital low-pass filter with independently adjustable cut-off frequency from 1 Hz to the full scope bandwidth. This enables you to reject noise on selected channels while viewing high-bandwidth signals on the others. An additional selectable analog bandwidth limiter on each input channel can be used to reject high frequencies that would otherwise cause aliasing.

Digital triggering

Most digital oscilloscopes sold today still use an analog trigger architecture based on comparators. This can cause time and amplitude errors that cannot always be calibrated out. The use of comparators often limits the trigger sensitivity at high bandwidths. In 1991 Pico pioneered the use of fully digital triggering using the actual digitized data. This technique reduces trigger errors and allows our oscilloscopes to trigger on the smallest signals, even at the full bandwidth. Trigger levels and hysteresis can be set with high precision and resolution.

Digital triggering also reduces re-arm delay and this, combined with the segmented memory, allows the triggering and capture of events that happen in rapid sequence. At the fastest timebase you can use rapid triggering to collect 10,000 waveforms in under 10 milliseconds.Advanced triggers The mask limit testing function can then scan through these waveforms to highlight any failed waveforms for viewing in the waveform buffer.

Advanced triggers

As well as the standard range of triggers found on most oscilloscopes, the PicoScope 6000 Series has a built-in set of advanced triggers to help you capture the data you need. All triggering is digital, resulting in high threshold resolution with programmable hysteresis and optimal waveform stability.

High signal integrity

High signal integrity

Most oscilloscopes are built down to a price; ours are built up to a specification.

Careful front–end design and shielding reduces noise, crosstalk and harmonic distortion. Years of oscilloscope experience leads to improved pulse response and bandwidth flatness. The result is simple: when you probe a circuit, you can trust in the waveform you see on the screen.

Hardware acceleration

On some oscilloscopes, enabling deep memory has a penalty: the screen update rate slows down and the controls become unresponsive as the processor struggles to cope with the amount of data. Thanks to the hardware acceleration inside PicoScope deep-memory oscilloscopes, you can collect waveforms containing hundreds of millions of samples while keeping fast screen update rates and a responsive user interface.

Hardware accelerationHardware acceleration ensures fast screen
update rates even when collecting
100,000,000 samples per waveform

Dedicated hardware inside the oscilloscope processes multiple streams of data in parallel to construct the waveform that will be displayed on the screen. This is done far faster than any PC processor could manage, and together with USB 3.0 SuperSpeed data transfer eliminates any bottlenecks between the oscilloscope and the PC.

 

For example, the scope may be set to capture 100,000,000 samples but the PicoScope display window may be only 1000 pixels wide. In this case, the scope intelligently compresses the data into 1000 blocks of 100 000 samples each. Unlike simple decimation, which throws away most of the data, PicoScope hardware acceleration guarantees that you see any high-frequency details such as narrow glitches, even when the display is zoomed out.

aggregationBoth waveforms show the same signal using different types of hardware acceleration.
Top waveform: using PicoScope hardware acceleration.
Bottom waveform: simulates the decimation used by many oscilloscopes — signal data is lost.

Ordering

 

PP838 PicoScope 6402A 250MHz, 128MB, Function generator, with probes
PP839 PicoScope 6402B 250MHz, 256MB, AWG, with probes
PP840 PicoScope 6403A 350MHz, 256MB, Function generator, with probes
PP841 PicoScope 6403B 350MHz, 512MB, AWG, with probes
PP842 PicoScope 6404A 500MHz, 512MB, Function generator, with probes
PP843 PicoScope 6404B 500MHz, 1GB, AWG, with probes
PP795 PicoScope 6407 1 GHz digitizer with case, no probes

 

Downloads

Enter your name and email to download DataSheet,UserManual



Name:
Email:
 

Specification

PicoScope 6400 USB Oscilloscope Specifications

Oscilloscope — Vertical
Model PicoScope 6402C PicoScope 6402D PicoScope 6403C PicoScope 6403D PicoScope 6404C PicoScope 6404D
Analog Bandwidth*
(-3 dB)
250 MHz
(200 MHz ±50 mV range)
350 MHz
(250 MHz ±50 mV range)
500 MHz
(all ranges)
Hardware Bandwidth limiter Switchable, 20 MHz Switchable, 25 MHz
Rise time
(10% to 90%, calculated)
1.4 ns (50 mV range 1.8 ns) 1.0 ns (50 mV range 1.4 ns) 0.7 ns (all ranges)
Vertical resolution 8 bits
Enhanced vertical resolution 12 bits
Input sensitivity 10 mV/div to 4 V/div at x1 zoom (1 MΩ input), 10 mV/div to 1 V/div at x1 zoom (50 Ω input)
Input ranges (full scale) ±50 mV to ±20V, in 9 ranges (1 MΩ input)
±50 mV to ±5V, in 7 ranges (50 Ω input)
Input characteristics 1 MΩ in parallel with 15 pF (AC or DC coupling) or 50 Ω (DC coupling) 1 MΩ in parallel with 10 pF (AC or DC coupling) or 50 Ω (DC coupling)
Analogue offset range
50 mV  to 200 mV ranges
500 mV range
1 V range
2 V range
5 V range
10 V range
20 V
Available offset
±0.5 V
±2.5 V
±2.5 V
±2.5 V
±20 V (50 Ω ±0.5 V)
±20 V
±20 V
Available offset
±2 V
±10 V (50 Ω ±5 V)
±10 V (50 Ω ±4.5 V)
±10 V (50 Ω ±3.5 V)
±35 V (50 Ω ±0.5 V)
±30 V
±20 V
DC accuracy 3% of full scale
Input type Single–ended, BNC connector
Overload protection ±100 V to ground (1 MΩ inputs), 5.5 V RMS (50 Ω inputs)

*Quoted bandwidth is with supplied probes or at BNC when 50 Ω impedance selected

Dynamic performance
Noise 200 μV RMS (50 mV range) 320 μV RMS (50 mV range)
THD –55 dB typical –54 dB typical
SFDR 60 dB typical 55 dB typical
Crosstalk 17 000:1 typical at 20 MHz
1000:1 typical at full bandwidth
5600:1 typical at 20 MHz
560:1 typical at full bandwidth
Oscilloscope — Horizontal
Maximum sampling rate (single shot)
1 channel in use
2 channels in use
3 or 4 ch. in use
5 GS/s
2.5 GS/s
1.25 GS/s
Maximum sampling rate (repetitive signals) 50 GS/s
Maximum sampling rate
(continuous streaming mode)
10 MS/s using PicoScope. >150 MS/s using the supplied SDK (PC dependent)
Buffer size
(shared between active channels)
256 MS 512 MS 512 MS 1 GS 1 GS 2 GS
Buffer size (streaming mode) 100 MS in PicoScope software. Up to available PC memory when using SDK.
Max. buffer segments (using PicoScope 6) 10,000
Maximum buffer segments (using SDK) 250,000 500,000 500,000 1,000,000 1,000,000 2,000,000
Timebase ranges
Real–time
ETS
1 ns/div to 5000 s/div
50 ps/div to 100 ns/div
Timebase accuracy ±2 ppm
Timebase ageing 1 ppm per year
Triggers
Basic triggers Rising, falling
Advanced triggers Edge: single edge or dual edge; adjustable hysteresis
Pulse width: negative or positive pulse; wider or narrower than a specified width
Window: entering or leaving a voltage range
Window pulse width: signal is inside or outside a voltage range for a set time
Dropout: inactivity over a user–defined time interval
Window dropout: signal does not enter or exit a voltage range for at least a set time
Delay: nth event after trigger event, with optional delay
Interval: time between two edges is greater or less than a set time, or inside/outside a time range
Level: the signal remains on one side of a threshold voltage for a specified period of time
Logic level: arbitrary logic state of Channels A to D and AUX
Runt pulse: crosses one threshold but not the other
Trigger modes None, Single, Repeat, Auto, Rapid, ETS
Maximum trigger rate Up to 10,000 waveforms in a 10 ms burst
Trigger sources Channels A to D, AUX
Trigger level Adjustable over whole of selected voltage range
Trigger sensitivity 1 LSB accuracy up to full bandwidth of scope
Re–arm time Less than 1 µs on fastest timebase
Maximum trigger delay
pre–trigger capture
post–trigger delay
100% of capture duration
4 billion samples
Trigger timing resolution 1 sample period
Auxiliary trigger Input (AUX)
AUX trigger connector type Rear panel BNC, shared with reference clock input
Trigger types Edge, pulse width, dropout, interval, logic
Input characteristics 50 Ω ±1%, DC coupled
Bandwidth 25 MHz
Threshold range ±1 V
Overvoltage protection ±5 V (DC + AC peak)
Reference clock Input (SDK only)
Clock input characteristics 50 Ω, BNC, ±1 V, DC coupled
Frequency range 5, 10, 20, 25 MHz, user-selectable
Connector Rear panel BNC, shared with AUX trigger
Level Adjustable threshold, ±1 V
Overvoltage protection ±5 V
Function generator and Arbitrary Waveform Generator
Frequency range DC to 20 MHz
Standard waveforms
All models
D models
Sine, square, triangle, DC level
Sine, square, triangle, DC level, ramp (up/down), sin (x)/x, Gaussian, half–sine, white noise, PRBS
Output frequency accuracy Same as scope timebase accuracy
Output frequency resolution < 0.05 Hz
DC accuracy ±1% of full scale
Connector type Rear panel BNC
Overvoltage protection ±5 V
Sweep modes Up, down, or dual, with selectable start/stop frequencies and increments
Signal generator triggering Scope, manual, or AUX input; programmable number of cycles from 1 to 1 billion
Amplitude range ±250 mV to ±2 V
Offset adjustment ±1 V (maximum combined output ±2.5 V)
Output impedance 50 Ω
AWG buffer size n/a 64 kS n/a 64 kS n/a 64 kS
AWG sample rate n/a 200 MS/s n/a 200 MS/s n/a 200 MS/s
AWG Resolution n/a 12 bits n/a 12 bits n/a 12 bits
Probe Compensation Output
Signal output type 1 kHz square wave, 2 V pk–pk, 600 Ω
Spectrum Analyzer
Frequency range DC to 250 MHz DC to 350 MHz DC to 500 MHz
Display modes Magnitude, peak hold, average
Windowing functions Rectangular, Gaussian, triangular, Blackman, Blackman–Harris, Hamming, Hann, flat–top
Number of FFT points From 128 to 1,048,576
Software
PicoScope 6 for Windows PicoScope 6 is your complete test and measurement lab in one application. Features include:
Capture modes: oscilloscope, spectrum and persistence.
Channel maths: calculate the sum, difference, product, inverse or create your own custom function using standard arithmetic, exponential and trigonometric functions.
Mask limiting testing: pass/fail, failure count, total count.
Serial Decoding: decode data from a serial bus such as I²C.
Automated measurements
Scope mode: AC RMS, true RMS, cycle time, DC average, duty cycle, falling rate, fall time, frequency, high pulse width, low pulse width, maximum, minimum, peak–to–peak, rise time and rising rate.
Spectrum mode: frequency at peak, amplitude at peak, average amplitude at peak, total power, total harmonic distortion (THD % and THD dB), total harmonic distortion plus noise (THD+N), spurious-free dynamic range (SFDR), signal+noise+distortion to signal+noise ratio (SINAD), signal to noise ratio (SNR) and intermodulation distortion (IMD).
Export data formats: comma separated values (CSV), tab delimited (TXT), Windows bitmap (BMP), graphics interchange format (GIF), portable network graphics (PNG), MATLAB 4 format (MAT).
Full details for PicoScope 6
Linux drivers 32–bit drivers
Software development kit Includes drivers and example code for various programming languages including C, C#, Excel and LabVIEW. Download SDK
PC Requirements
Minimum Processor: 1 GHz
Memory: 512 MiB
Free disk space: 32–bit: 600 MB, 64–bit: 1.5 GB
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT)
Ports: USB 2.0 compliant port
Recommended Processor: 1 GHz
Memory: 512 MiB
Free disk space: 32–bit: 850 MB, 64–bit: 2 GB
Operating system: 32– or 64–bit edition of Microsoft Windows XP (SP3), Vista, Windows 7 or Windows 8 (not Windows RT)
Ports: USB 3.0 compliant port
Environmental
Operating environment
Temperature  range
Humidity
0 °C to 40 °C (20 °C to 30 °C for quoted accuracy)
5 to 80% RH, non–condensing
Storage environment
Temperature  range
Humidity
-20 to +60 °C
5 to 95% RH, non–condensing
Physical Properties
Dimensions 255 x 170 x 40 mm
(approx 10 x 6.7 x 1.6 in)
280 x 170 x 40 mm
(approx 11 x 6.7 x 1.6 in)
Weight 1 kg
(approx 2 lb  3 oz)
1.3 kg
(approx 2 lb  14 oz)
Language Support
Software
PicoScope 6
Full support for: English, Deutsch, Español, Français, Italiano
Menus and dialogs only for: 中文 (简体), 中文 (繁體), Čeština, Dansk, suomi, Ελληνικά, Magyar, 한국어, 日本語, Norsk, Polski, Português, română, Русский, Svenska, Türkçe
Documentation
User’s guide
Programmer’s guide
Quick Start Guide
English, 中文 (简体), Deutsch, Español, Français, Italiano
English
English, Deutsch, Español, Français, Italiano
General
Data sheet English
Additional hardware (supplied) Four factory–compensated oscilloscope probes, USB 3.0 cable, universal mains (AC) power supply, mains lead (power cord), carry case, user manuals and software CD–ROM
PC interface USB 3.0 (USB 2.0 compatible)
Power supply
AC adaptor
12 V @ 4 A
External adaptor supplied (suitable for USA, UK, Europe and Australasia)
Compliance European EMC and LVD standards
FCC Rules Part 15 Class A
RoHS compliant
Total Satisfaction Guarantee In the event that this product does not fully meet your requirements you can return it for an exchange or refund. To claim, the product must be returned in good condition within 14 days.
Warranty 5 years
Ordering information
Model 6402C 6402D 6403C 6403D 6404C 6404D
Channels 4 4 4 4 4 4
Bandwidth 250 MHz 250 MHz 350 MHz 350 MHz 500 MHz 500 MHz
Memory 256 MS 512 MS 512 MS 1 GS 1 GS 2 GS
138 queries in 6.807 seconds.